Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

LADDERLOGIX 6306f71c981554000164a40c Products https://www.ladderlogixindia.com
1-channel isolated b
1-channel isolated b
COD not available
SMART Transmitter Power Supply by PEPPERL-FUCHS

KCD2-STC-Ex1.2O

Description

Product details

1-channel isolated barrier 24 V DC supply (Power Rail) Input for 2-wire SMART transmitters and current sources Signal splitter (1 input and 2 outputs) Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V Terminal blocks with test sockets SIL 2 (SC 3) acc. to IEC/EN 61508 General specifications Signal type Analog input Functional safety related parameters Safety Integrity Level (SIL) SIL 2 Systematic capability (SC) SC 3 Supply Connection Power Rail or terminals 9+, 10- Rated voltage 19 ... 30 V DC Ripple within the supply tolerance Power dissipation approx. 1.4 W at 20 mA transfer current, 250 Ω in both outputs Power consumption 2 W Input Connection side field side Connection terminals 1+, 2- (sink); 3+, 4- (source) Input signal 0/4 ... 20 mA Voltage drop terminals 3, 4: ≤ 6.1 V at 20 mA Short-circuit current terminals 1+, 2-: 25 mA Input resistance terminals 1+, 2-: max. 500 Ω (BRAIN) (250 Ω load) Available voltage terminals 1+, 2-: ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA Output Connection side control side Connection source: terminals 5-, 6+; 7-, 8+ sink: terminals 5+, 6-, 7+, 8- Load channel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) channel 2: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) Output signal 0/4 ... 20 mA or 0/1 ... 5 V Ripple max. 50 µA rms Transfer characteristics Deviation Iout < 20 µA (0.1 %); Vout < 10 mV (0.2 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 °C (68 °F), 0/4 ... 20 mA, 0/1 ... 5 V Influence of ambient temperature current output: 0.25 µA/K voltage output: 80 µV/K Frequency range field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 6 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 6 kHz (-3 dB) Settling time 6 ms Rise time/fall time 2 ms Galvanic isolation Output/power supply functional insulation, rated insulation voltage 50 V AC Output/Output functional insulation, rated insulation voltage 50 V AC Indicators/settings Display elements LED Control elements DIP switch Configuration via DIP switches Labeling space for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 (industrial locations) Conformity Electromagnetic compatibility NE 21:2012 EN 61326-3-2:2008 Degree of protection IEC 60529:2001 Protection against electrical shock UL 61010-1:2012 Ambient conditions Ambient temperature -20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions Mechanical specifications Degree of protection IP20 Connection screw terminals Mass approx. 100 g Dimensions 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2 Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001 Data for application in connection with hazardous areas EU-type examination certificate BASEEFA 13 ATEX 0077 X Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC Ex-Hexagon II (1)D [Ex ia Da] IIIC Ex-Hexagon I (M1) [Ex ia Ma] I Input [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Supply Maximum safe voltage 250 V (Attention! The rated voltage can be lower.) Equipment terminals 1+, 2- Voltage 25.2 V Voltage 28.2 V Current 93 mA Power 656 mW Internal capacitance 10 nF Internal inductance 0 mH Equipment terminals 3+, 4- Voltage 30 V Current 115 mA Power 700 mW Voltage 5 V Current 6.8 mA Power 1.6 mW Output Maximum safe voltage 250 V (Attention! The rated voltage can be lower.) Certificate BASEEFA 13 ATEX 0078 X Marking Ex-Hexagon II 3G Ex nA II T4 Gc [device in zone 2] Galvanic isolation Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 International approvals UL approval Control drawing 116-0380 (cULus) IECEx approval IECEx certificate IECEx BAS 13.0043X IECEx marking [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us