Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

LADDERLOGIX 6306f71c981554000164a40c Products https://www.ladderlogixindia.com
{ "products": [ { "_id": "63eb63a605aabd0001b23525", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Safety contacts", "description": "2 safety contacts\nPROTECT -IE-02\nSignalling output for each sensor (monitoring of both circuits of the sensors) and and all sensors (Y5, group signal)\n\nInput for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emergency stop devices, interlocking devices and others\n\nPossibility to connect up to 4 sensors with non-isolated signals, e.g. the CSS products from Schmersal as well as AOPD’s (only PROTECT-PE-02\n\n", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "BNS", "AOPD", "Input", "others", "PROTECT", "circuits", "Schmersal", "interface", "monitoring", "Possibility", "group signal", "CSS products", "up to 4 sensors", "isolated signals", "Signalling output", "2 safety contacts", "interlocking devices", "emergency stop devices", "magnetic safety switches" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 161, "imageuri": "https://productimages.withfloats.com/actual/63eb63abdd41810001667562.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63eb63abdd41810001667562.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-14T10:34:14.729Z", "updatedon": "2025-07-17T04:34:18.491Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM/products/safety-contacts/161", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL ", "category": "SCHMERSAL", "tags": [ "Safety contacts in India", "Safety contacts supplier in Vadodara" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e1582c5dc8b0001d08820", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KCD2-SR-Ex2", "description": "2-channel isolated barrier\n24 V DC supply (Power Rail)\nDry contact or NAMUR inputs\nRelay contact output\nLine fault detection (LFD)\nHousing width 12.5 mm\nUp to SIL 2 acc. to IEC/EN 61508\nGeneral specifications\nSignal type\tDigital Input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSupply\nConnection\tPower Rail or terminals 9+, 10-\nRated voltage\t19 ... 30 V DC\nRipple\t≤ 10 %\nRated current\t≤ 46 mA\nPower dissipation\t≤ 900 mW\nPower consumption\t≤ 900 mW\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2-; 3+, 4-\nRated values\tacc. to EN 60947-5-6 (NAMUR)\nOpen circuit voltage/short-circuit current\tapprox. 8 V DC / approx. 8 mA\nSwitching point/switching hysteresis\t1.2 ... 2.1 mA / approx. 0.2 mA\nLine fault detection\tbreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA\nPulse/Pause ratio\tmin. 20 ms / min. 20 ms\nOutput\nConnection side\tcontrol side\nConnection\tterminals 5, 6; 7, 8\nOutput I\tsignal ; relay\nOutput II\tsignal ; relay\nContact loading\t250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load\nMinimum switch current\t2 mA / 24 V DC\nEnergized/De-energized delay\t≤ 20 ms / ≤ 20 ms\nMechanical life\t107 switching cycles\nTransfer characteristics\nSwitching frequency\t≤ 10 Hz\nGalvanic isolation\nInput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nInput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nIndicators/settings\nDisplay elements\tLEDs\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nLow voltage\t\nDirective 2014/35/EU\tEN 61010-1:2010+A1:2019+A1:2019/AC:2019\nConformity\nElectromagnetic compatibility\tNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018\nDegree of protection\tIEC 60529:1989+A1:1999+A2:2013\nFunctional safety\tIEC/EN 61508:2010\nInput\tEN 60947-5-6:2000\nAmbient conditions\nAmbient temperature\t-40 ... 70 °C (-40 ... 158 °F)\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 100 g\nDimensions\t12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tBASEEFA 06 ATEX 0092 X\nMarking\tEx-Hexagon II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I\nInput\tEx ia\nVoltage\t10.5 V\nCurrent\t13 mA\nPower\t34 mW (linear characteristic)\nSupply\t\nMaximum safe voltage\t253 V AC (Attention! Um is no rated voltage.)\nOutput\t\nContact loading\tZone 2 : 50 V AC/2 A/cos φ > 0.75; 30 V DC/2 A resistive load\nMaximum safe voltage\t253 V AC (Attention! The rated voltage can be lower.)\nFault indication output\t\nMaximum safe voltage\t40 V DC (Attention! Um is no rated voltage.)\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019\nInternational approvals\nUL approval\tE106378\nControl drawing\t116-0477 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx BAS 06.0025 X\nIECEx marking\tEx ec nC [ia Ga] IIC T4 Gc\n[Ex ia Da] IIIC\n[Ex ia Ma] I", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "V AC", "30 V", "24 V", "EN IEC", "8 V DC", "Ex ia Da", "SIL 2 acc", "V DC supply", "x 119 x 114 mm", "industrial locations", "linear characteristic", "insulation voltage 300", "voltage peak value 375", "electrical isolation acc" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 55, "imageuri": "https://productimages.withfloats.com/actual/635e15845d8f8c0001fd05b6.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/635e15845d8f8c0001fd05b6.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T06:11:14.65Z", "updatedon": "2022-10-30T06:11:14.65Z", "buyonlinelink": null, "producturl": "http://WWW.LADDERLOGIXINDIA.COM/products/kcd2-sr-ex2/55", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": "Switch Amplifier", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e143fc5dc8b0001d08818", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KFD2-SR2-Ex2.W", "description": "2-channel isolated barrier\n24 V DC supply (Power Rail)\nDry contact or NAMUR inputs\nRelay contact output\nLine fault detection (LFD)\nReversible mode of operation\nUp to SIL 2 acc. to IEC 61508/IEC 61511\nGeneral specifications\nSignal type\tDigital Input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSupply\nConnection\tPower Rail or terminals 14+, 15-\nRated voltage\t19 ... 30 V DC\nRipple\t≤ 10 %\nRated current\t≤ 50 mA\nPower dissipation\t≤ 1 W\nPower consumption\t≤ 1 W\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2+, 3-; 4+, 5+, 6-\nRated values\tacc. to EN 60947-5-6 (NAMUR)\nOpen circuit voltage/short-circuit current\tapprox. 8 V DC / approx. 8 mA\nSwitching point/switching hysteresis\t1.2 ... 2.1 mA / approx. 0.2 mA\nLine fault detection\tbreakage I ≤ 0.1 mA , short-circuit I > 6 mA\nPulse/Pause ratio\tmin. 20 ms / min. 20 ms\nOutput\nConnection side\tcontrol side\nConnection\toutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12\nOutput I, II\tsignal, relay\nContact loading\t250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load\nMinimum switch current\t2 mA / 24 V DC\nEnergized/De-energized delay\tapprox. 20 ms / approx. 20 ms\nMechanical life\t107 switching cycles\nCollective error message\tPower Rail\nTransfer characteristics\nSwitching frequency\t≤ 10 Hz\nGalvanic isolation\nInput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nInput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nIndicators/settings\nDisplay elements\tLEDs\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nLow voltage\t\nDirective 2014/35/EU\tEN 61010-1:2010+A1:2019+A1:2019/AC:2019\nConformity\nElectromagnetic compatibility\tNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018\nDegree of protection\tIEC 60529:1989+A1:1999+A2:2013\nFunctional safety\tIEC/EN 61508:2010\nInput\tEN 60947-5-6:2000\nAmbient conditions\nAmbient temperature\t-20 ... 70 °C (-4 ... 158 °F)\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 150 g\nDimensions\t20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tPTB 00 ATEX 2080\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC\nEx-Hexagon II (1)D [Ex ia Da] IIIC\nEx-Hexagon I (M1) [Ex ia Ma] I\nInput\tEx ia\nVoltage\t10.5 V\nCurrent\t13 mA\nPower\t34 mW (linear characteristic)\nSupply\t\nMaximum safe voltage\t253 V AC / 125 V DC (Attention! Um is no rated voltage.)\nOutput\t\nMaximum safe voltage\t253 V AC (Attention! The rated voltage can be lower.)\nFault indication output\t\nMaximum safe voltage\t40 V DC (Attention! Um is no rated voltage.)\nCertificate\tPF 08 CERT 0803\nMarking\tEx-Hexagon II (3)G [Ex ic Gc] IIC\nInput\tEx ic\nVoltage\t10.5 V\nCurrent\t13 mA\nPower\t34 mW (linear characteristic)\nCertificate\tTÜV 99 ATEX 1493 X\nMarking\tEx-Hexagon II 3G Ex ec nC IIC T4 Gc\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019\nInternational approvals\nFM approval\t\nFM certificate\tFM19US0207X\nControl drawing\t116-0035\nUL approval\tE106378\nControl drawing\t116-0473 (cULus)\nContact loading\t250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load\nIECEx approval\t\nIECEx certificate\tIECEx PTB 11.0034 , IECEx TUN 19.0013X\nIECEx marking\t[Ex ia Ga] IIC\n[Ex ia Da] IIIC\n[Ex ia Ma] I\nEx ec nC IIC T4 Gc", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "V AC", "30 V", "24 V", "40 V", "8 V DC", "EN IEC", "125 V DC", "SIL 2 acc", "V DC supply", "x 119 x 115 mm", "II 3G Ex ec nC IIC T4", "linear characteristic", "insulation voltage 300", "voltage peak value 375", "electrical isolation acc" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 54, "imageuri": "https://productimages.withfloats.com/actual/635e14415d8f8c0001fd059e.png", "tileimageuri": "https://productimages.withfloats.com/tile/635e14415d8f8c0001fd059e.png", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T06:05:51.646Z", "updatedon": "2022-10-30T06:05:51.646Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM//kfd2-sr2-ex2-w/54", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": "Switch Amplifier", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e135d36a6d00001c423ff", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KCD2-SR-Ex1.LB", "description": "1-channel isolated barrier\n24 V DC supply (Power Rail)\nDry contact or NAMUR inputs\nUsable as signal splitter (1 input and 2 outputs)\nRelay contact output\nFault relay contact output\nLine fault detection (LFD)\nHousing width 12.5 mm\nUp to SIL 2 acc. to IEC/EN 61508\nGeneral specifications\nSignal type\tDigital Input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSupply\nConnection\tPower Rail or terminals 9+, 10-\nRated voltage\t19 ... 30 V DC\nRipple\t≤ 10 %\nRated current\t≤ 37 mA\nPower dissipation\t≤ 750 mW\nPower consumption\t≤ 750 mW\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2-\nRated values\tacc. to EN 60947-5-6 (NAMUR)\nOpen circuit voltage/short-circuit current\tapprox. 8 V DC / approx. 8 mA\nSwitching point/switching hysteresis\t1.2 ... 2.1 mA / approx. 0.2 mA\nLine fault detection\tbreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA\nPulse/Pause ratio\tmin. 20 ms / min. 20 ms\nOutput\nConnection side\tcontrol side\nConnection\toutput I: terminals 5, 6 ; output II: terminals 7, 8\nOutput I\tsignal ; relay\nOutput II\tsignal or error message ; relay\nContact loading\t250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load\nMinimum switch current\t2 mA / 24 V DC\nEnergized/De-energized delay\t≤ 20 ms / ≤ 20 ms\nMechanical life\t107 switching cycles\nTransfer characteristics\nSwitching frequency\t≤ 10 Hz\nGalvanic isolation\nInput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nInput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nIndicators/settings\nDisplay elements\tLEDs\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nLow voltage\t\nDirective 2014/35/EU\tEN 61010-1:2010+A1:2019+A1:2019/AC:2019\nConformity\nElectromagnetic compatibility\tNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018\nDegree of protection\tIEC 60529:1989+A1:1999+A2:2013\nFunctional safety\tIEC/EN 61508:2010\nInput\tEN 60947-5-6:2000\nAmbient conditions\nAmbient temperature\t-40 ... 70 °C (-40 ... 158 °F)\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 100 g\nDimensions\t12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tBASEEFA 06 ATEX 0092 X\nMarking\tEx-Hexagon II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I\nInput\tEx ia\nVoltage\t10.5 V\nCurrent\t13 mA\nPower\t34 mW (linear characteristic)\nSupply\t\nMaximum safe voltage\t253 V AC (Attention! Um is no rated voltage.)\nOutput\t\nContact loading\tZone 2 : 50 V AC/2 A/cos φ > 0.75; 30 V DC/2 A resistive load\nMaximum safe voltage\t253 V AC (Attention! The rated voltage can be lower.)\nFault indication output\t\nMaximum safe voltage\t40 V DC (Attention! Um is no rated voltage.)\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019\nInternational approvals\nUL approval\tE106378\nControl drawing\t116-0477 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx BAS 06.0025 X\nIECEx marking\tEx ec nC [ia Ga] IIC T4 Gc\n[Ex ia Da] IIIC\n[Ex ia Ma] I", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "V AC", "30 V", "EN IEC", "8 V DC", "1 input", "SIL 2 acc", "2 outputs", "V DC supply", "terminals 5", "x 119 x 114 mm", "linear characteristic", "insulation voltage 300", "voltage peak value 375", "electrical isolation acc" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 53, "imageuri": "https://productimages.withfloats.com/actual/635e135fc7b01e0001eb35f1.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/635e135fc7b01e0001eb35f1.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T06:02:05.554Z", "updatedon": "2022-10-30T06:02:05.554Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM//kcd2-sr-ex1-lb/53", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": "Switch Amplifier", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e123fa2024c00014bc30f", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KFD2-SR2-Ex1.W.LB", "description": "1-channel isolated barrier\n24 V DC supply (Power Rail)\nDry contact or NAMUR inputs\nUsable as signal splitter (1 input and 2 outputs)\nRelay contact output\nFault relay contact output\nLine fault detection (LFD)\nReversible mode of operation\nUp to SIL 2 acc. to IEC 61508/IEC 61511\nGeneral specifications\nSignal type\tDigital Input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSupply\nConnection\tPower Rail or terminals 14+, 15-\nRated voltage\t19 ... 30 V DC\nRipple\t≤ 10 %\nRated current\t≤ 45 mA\nPower dissipation\t≤ 0.9 W\nPower consumption\t≤ 0.9 W\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2+, 3-\nRated values\tacc. to EN 60947-5-6 (NAMUR)\nOpen circuit voltage/short-circuit current\tapprox. 8 V DC / approx. 8 mA\nSwitching point/switching hysteresis\t1.2 ... 2.1 mA / approx. 0.2 mA\nLine fault detection\tbreakage I ≤ 0.1 mA , short-circuit I > 6 mA\nPulse/Pause ratio\tmin. 20 ms / min. 20 ms\nOutput\nConnection side\tcontrol side\nConnection\toutput I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12\nOutput I\tsignal ; relay\nOutput II\tsignal or fault message ; relay\nContact loading\t250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load\nMinimum switch current\t2 mA / 24 V DC\nEnergized/De-energized delay\tapprox. 20 ms / approx. 20 ms\nMechanical life\t107 switching cycles\nCollective error message\tPower Rail\nTransfer characteristics\nSwitching frequency\t≤ 10 Hz\nGalvanic isolation\nInput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nInput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/Output\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nIndicators/settings\nDisplay elements\tLEDs\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nLow voltage\t\nDirective 2014/35/EU\tEN 61010-1:2010+A1:2019+A1:2019/AC:2019\nConformity\nElectromagnetic compatibility\tNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018\nDegree of protection\tIEC 60529:1989+A1:1999+A2:2013\nFunctional safety\tIEC/EN 61508:2010\nInput\tEN 60947-5-6:2000\nAmbient conditions\nAmbient temperature\t-20 ... 70 °C (-4 ... 158 °F)\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 150 g\nDimensions\t20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tPTB 00 ATEX 2080\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC\nEx-Hexagon II (1)D [Ex ia Da] IIIC\nEx-Hexagon I (M1) [Ex ia Ma] I\nInput\tEx ia\nVoltage\t10.5 V\nCurrent\t13 mA\nPower\t34 mW (linear characteristic)\nSupply\t\nMaximum safe voltage\t253 V AC / 125 V DC (Attention! Um is no rated voltage.)\nOutput\t\nMaximum safe voltage\t253 V AC (Attention! The rated voltage can be lower.)\nFault indication output\t\nMaximum safe voltage\t40 V DC (Attention! Um is no rated voltage.)\nCertificate\tPF 08 CERT 0803\nMarking\tEx-Hexagon II (3)G [Ex ic Gc] IIC\nInput\tEx ic\nVoltage\t10.5 V\nCurrent\t13 mA\nPower\t34 mW (linear characteristic)\nCertificate\tTÜV 99 ATEX 1493 X\nMarking\tEx-Hexagon II 3G Ex ec nC IIC T4 Gc\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019\nInternational approvals\nFM approval\t\nFM certificate\tFM19US0207X\nControl drawing\t116-0035\nUL approval\tE106378\nControl drawing\t116-0473 (cULus)\nContact loading\t250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load\nIECEx approval\t\nIECEx certificate\tIECEx PTB 11.0034 , IECEx TUN 19.0013X\nIECEx marking\t[Ex ia Ga] IIC\n[Ex ia Da] IIIC\n[Ex ia Ma] I\nEx ec nC IIC T4 Gc", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "V AC", "30 V", "24 V", "40 V", "8 V DC", "EN IEC", "125 V DC", "SIL 2 acc", "V DC supply", "x 119 x 115 mm", "II 3G Ex ec nC IIC T4", "linear characteristic", "insulation voltage 300", "voltage peak value 375", "electrical isolation acc" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 52, "imageuri": "https://productimages.withfloats.com/actual/635e12405d8f8c0001fd0509.png", "tileimageuri": "https://productimages.withfloats.com/tile/635e12405d8f8c0001fd0509.png", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T05:57:19.18Z", "updatedon": "2022-10-30T05:57:19.18Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM//kfd2-sr2-ex1-w-lb/52", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": "Switch Amplifier", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e110bf7c0e00001ca7e77", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KCD2-STC-Ex1.2O", "description": "1-channel isolated barrier\n24 V DC supply (Power Rail)\nInput for 2-wire SMART transmitters and current sources\nSignal splitter (1 input and 2 outputs)\nDual output 0/4 mA ... 20 mA or 0/1 V ... 5 V\nTerminal blocks with test sockets\nSIL 2 (SC 3) acc. to IEC/EN 61508\nGeneral specifications\nSignal type\tAnalog input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSystematic capability (SC)\tSC 3\nSupply\nConnection\tPower Rail or terminals 9+, 10-\nRated voltage\t19 ... 30 V DC\nRipple\twithin the supply tolerance\nPower dissipation\tapprox. 1.4 W at 20 mA transfer current, 250 Ω in both outputs\nPower consumption\t2 W\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2- (sink); 3+, 4- (source)\nInput signal\t0/4 ... 20 mA\nVoltage drop\tterminals 3, 4: ≤ 6.1 V at 20 mA\nShort-circuit current\tterminals 1+, 2-: 25 mA\nInput resistance\tterminals 1+, 2-: max. 500 Ω (BRAIN)\n(250 Ω load)\nAvailable voltage\tterminals 1+, 2-: ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA\nOutput\nConnection side\tcontrol side\nConnection\tsource: terminals 5-, 6+; 7-, 8+\nsink: terminals 5+, 6-, 7+, 8-\nLoad\tchannel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V)\nchannel 2: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V)\nOutput signal\t0/4 ... 20 mA or 0/1 ... 5 V\nRipple\tmax. 50 µA rms\nTransfer characteristics\nDeviation\tIout < 20 µA (0.1 %); Vout < 10 mV (0.2 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 °C (68 °F), 0/4 ... 20 mA, 0/1 ... 5 V\nInfluence of ambient temperature\tcurrent output: 0.25 µA/K\nvoltage output: 80 µV/K\nFrequency range\tfield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 6 kHz (-3 dB)\ncontrol side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 6 kHz (-3 dB)\nSettling time\t6 ms\nRise time/fall time\t2 ms\nGalvanic isolation\nOutput/power supply\tfunctional insulation, rated insulation voltage 50 V AC\nOutput/Output\tfunctional insulation, rated insulation voltage 50 V AC\nIndicators/settings\nDisplay elements\tLED\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nConformity\nElectromagnetic compatibility\tNE 21:2012\nEN 61326-3-2:2008\nDegree of protection\tIEC 60529:2001\nProtection against electrical shock\tUL 61010-1:2012\nAmbient conditions\nAmbient temperature\t-20 ... 60 °C (-4 ... 140 °F)\nextended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 100 g\nDimensions\t12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tBASEEFA 13 ATEX 0077 X\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC\nEx-Hexagon II (1)D [Ex ia Da] IIIC\nEx-Hexagon I (M1) [Ex ia Ma] I\nInput\t[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\nSupply\t\nMaximum safe voltage\t250 V (Attention! The rated voltage can be lower.)\nEquipment\tterminals 1+, 2-\nVoltage\t25.2 V\nVoltage\t28.2 V\nCurrent\t93 mA\nPower\t656 mW\nInternal capacitance\t10 nF\nInternal inductance\t0 mH\nEquipment\tterminals 3+, 4-\nVoltage\t30 V\nCurrent\t115 mA\nPower\t700 mW\nVoltage\t5 V\nCurrent\t6.8 mA\nPower\t1.6 mW\nOutput\t\nMaximum safe voltage\t250 V (Attention! The rated voltage can be lower.)\nCertificate\tBASEEFA 13 ATEX 0078 X\nMarking\tEx-Hexagon II 3G Ex nA II T4 Gc [device in zone 2]\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010\nInternational approvals\nUL approval\t\nControl drawing\t116-0380 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx BAS 13.0043X\nIECEx marking\t[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\n", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "5 V", "1 input", "Ex ia Da", "Ex ia Ma", "Ex ia Ga", "V DC supply", "Vpp signal 0", "supply voltage", "20 mA transfer current", "voltage peak value 375", "insulation voltage 50 V", "electrical isolation acc", "ambient temperature range", "35 mm DIN mounting rail acc" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 51, "imageuri": "https://productimages.withfloats.com/actual/635e110be52a05000198bd1d.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/635e110be52a05000198bd1d.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T05:52:11.653Z", "updatedon": "2022-10-30T05:52:11.653Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM//kcd2-stc-ex1-2o/51", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": " SMART Transmitter Power Supply", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e0b9544ad890001abb9fc", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KCD2-STC-Ex1", "description": "1-channel isolated barrier\n24 V DC supply (Power Rail)\nInput for 2-wire SMART transmitters and current sources\nOutput for 4 mA ... 20 mA or 1 V ... 5 V\nHousing width 12.5 mm\nSIL 2 (SC 3) acc. to IEC/EN 61508\n\nGeneral specifications\nSignal type\tAnalog input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSystematic capability (SC)\tSC 3\nSupply\nConnection\tPower Rail or terminals 9+, 10-\nRated voltage\t19 ... 30 V DC\nRipple\t≤ 10 %\nRated current\t≤ 45 mA at 24 V and 20 mA source mode output\nPower dissipation\t≤ 800 mW\nPower consumption\t≤ 1.1 W\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2-; 3+, 4-\nInput signal\t4 ... 20 mA limited to approx. 26 mA\nOpen circuit voltage/short-circuit current\tterminals 1+, 2-: 22 V / 26 mA\nVoltage drop\tterminals 3+, 4- : approx. 5 V\nAvailable voltage\tterminals 1+, 2-: ≥ 15 V at 20 mA ; ≥ 18 V at 4 mA\nOutput\nConnection side\tcontrol side\nConnection\tterminals 5-, 6+\nterminals 5-, 8+ for HART resistor\nLoad\t0 ... 350 Ω (source mode)\nOutput signal\t4 ... 20 mA or 1 ... 5 V (on 250 Ω, 0.1 % internal shunt)\n4 ... 20 mA (sink mode), operating voltage 10 ... 30 V\nRipple\t20 mV rms\nTransfer characteristics\nDeviation\tat 20 °C (68 °F)\n< 0.1 % of full scale, incl. non-linearity and hysteresis (source mode and sink mode 4 ... 20 mA)\n≤ ± 0.2 % incl. non-linearity and hysteresis (source mode 1 ... 5 V)\nInfluence of ambient temperature\t< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode and sink mode 4 ... 20mA)\n< 0.5 mV/K (-20 ... 70 °C (-4 ... 158 °F)); < 1 mV/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode 1...5 V)\nFrequency range\tfield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)\ncontrol side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)\nSettling time\t≤ 50 ms\nRise time/fall time\t≤ 10 ms\nGalvanic isolation\nInput/Output\tbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nInput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/power supply\tbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nIndicators/settings\nDisplay elements\tLED\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nConformity\nElectromagnetic compatibility\tNE 21:2017\nEN 61326-3-2:2018\nDegree of protection\tIEC 60529:2001\nProtection against electrical shock\tUL 61010-1:2012\nAmbient conditions\nAmbient temperature\t-40 ... 70 °C (-40 ... 158 °F)\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 100 g\nDimensions\t12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tCESI 06 ATEX 021\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC\nEx-Hexagon II (1)D [Ex ia Da] IIIC\nEx-Hexagon I (M1) [Ex ia Ma] I\nInput\tEx ia\nSupply\t\nMaximum safe voltage\t250 V AC (Attention! Um is no rated voltage.)\nEquipment\tterminals 1+, 2-\nVoltage\t25.2 V\nCurrent\t100 mA\nPower\t630 mW\nInternal capacitance\t5.7 nF\nInternal inductance\tnegligible\nEquipment\tterminals 3+, 4-\nVoltage\t30 V\nCurrent\t128 mA\nVoltage\t7.2 V\nCurrent\t100 mA\nPower\t25 mW\nInternal capacitance\t5.7 nF\nInternal inductance\tnegligible\nCertificate\tCESI 19 ATEX 021 X\nMarking\tEx-Hexagon II 3G Ex ec IIC T4 Gc\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-7:2015\nInternational approvals\nFM approval\t\nFM certificate\tFM 18 CA 0116 X , FM 19 US 0117 X\nControl drawing\t116-0469 (cFMus)\nUL approval\tE106378\nControl drawing\t116-0459 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx CES 06.0001X\nIECEx marking\t[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I\nEx ec IIC T4 Gc", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "1 V", "5 V", "4 mA", "mode 4", "V DC supply", "Vpp signal 0", "source mode 1", "20 mA source mode", "II 3G Ex ec IIC T4", "operating voltage 10", "insulation voltage 300", "voltage peak value 375", "electrical isolation acc", "SMART Transmitter Power Supply" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 49, "imageuri": "https://productimages.withfloats.com/actual/635e0b97bb77e100018dfb6c.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/635e0b97bb77e100018dfb6c.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T05:28:53.901Z", "updatedon": "2022-10-30T05:36:42.667Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM/products/kcd2-stc-ex1/49", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": "SMART Transmitter Power Supply", "tags": [], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "63f6f9772f43e500010f1eea", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "FLEXIBLE CLOSE-RADIUS ACTUATOR KEY", "description": "AZ17-B6 - SCHMERSAL FLEXIBLE CLOSE-RADIUS ACTUATOR KEY The compact Series AZ17 is designed for use with movable machine guards/access gates which must be closed for operator safety. Their positive-opening NC contacts provide a significantly higher level of safety than conventional springdriven switches whose contacts can weld or stick shut. And their tamper-resistant design prevents bypassing with simple tools, bent wires or other readily available means. Their IP67 rating makes them ideal for interlocking safety guards in hostile environments", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "use", "other", "bent wires", "IP67 rating", "ACTUATOR AZ", "higher level", "simple tools", "safety guards", "available means", "operator safety", "compact Series AZ17", "hostile environments", "tamper-resistant design", "positive-opening NC contacts", "conventional springdriven switches", "movable machine guards/access gates", "SCHMERSAL FLEXIBLE CLOSE-RADIUS ACTUATOR KEY" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 182, "imageuri": "https://productimages.withfloats.com/actual/63f6f97c5485af0001f0de54.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63f6f97c5485af0001f0de54.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-23T05:28:23.748Z", "updatedon": "2025-07-16T10:19:02.493Z", "buyonlinelink": null, "producturl": "http://WWW.LADDERLOGIXINDIA.COM/products/flexible-close-radius-actuator-key/182", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL ", "category": "FLEXIBLE CLOSE-RADIUS ACTUATOR KEY ", "tags": [ "ACTUATOR AZ 17-B6 In Vadodara ", "ACTUATOR AZ 17-B6 In India " ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "63ef0d13283db8000193bc8d", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Safety actuator", "description": "Safety actuator AZ17-B6 - 101126060 from Schmersal is a 0° or 90° angled actuator and is compatible with AZ 17 safety switches.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "Schmersal", "B6 Safety actuator", "90° angled actuator", "AZ 17 safety switches" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 171, "imageuri": "https://productimages.withfloats.com/actual/63ef0d1a1c67bc0001515501.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63ef0d1a1c67bc0001515501.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-17T05:13:55.338Z", "updatedon": "2025-07-16T11:03:36.763Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM//safety-actuator/171", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL ", "category": "SAFTEY SWITCH ", "tags": [ "Safety actuator in India" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
magnetic safety switches?

Still searching for
magnetic safety switches?

Chat with us