Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

LADDERLOGIX 6306f71c981554000164a40c Products https://www.ladderlogixindia.com
{ "products": [ { "_id": "63f6f9772f43e500010f1eea", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "FLEXIBLE CLOSE-RADIUS ACTUATOR KEY", "description": "AZ17-B6 - SCHMERSAL FLEXIBLE CLOSE-RADIUS ACTUATOR KEY The compact Series AZ17 is designed for use with movable machine guards/access gates which must be closed for operator safety. Their positive-opening NC contacts provide a significantly higher level of safety than conventional springdriven switches whose contacts can weld or stick shut. And their tamper-resistant design prevents bypassing with simple tools, bent wires or other readily available means. Their IP67 rating makes them ideal for interlocking safety guards in hostile environments", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "use", "other", "bent wires", "IP67 rating", "ACTUATOR AZ", "higher level", "simple tools", "safety guards", "available means", "operator safety", "compact Series AZ17", "hostile environments", "tamper-resistant design", "positive-opening NC contacts", "conventional springdriven switches", "movable machine guards/access gates", "SCHMERSAL FLEXIBLE CLOSE-RADIUS ACTUATOR KEY" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 182, "imageuri": "https://productimages.withfloats.com/actual/63f6f97c5485af0001f0de54.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63f6f97c5485af0001f0de54.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-23T05:28:23.748Z", "updatedon": "2025-07-16T10:19:02.493Z", "buyonlinelink": null, "producturl": "http://WWW.LADDERLOGIXINDIA.COM/products/flexible-close-radius-actuator-key/182", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL ", "category": "FLEXIBLE CLOSE-RADIUS ACTUATOR KEY ", "tags": [ "ACTUATOR AZ 17-B6 In Vadodara ", "ACTUATOR AZ 17-B6 In India " ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "63f6f5087688aa000154f184", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "M6 for Pull Wire Switches", "description": "Schmersal Tensioner M6 for Pull Wire Switches M6-TENSIONING JACK-SS316 Schmersal tensioning jack for use with ZQ series pull wire emergency stop switches.\n\nFor exact adjustment of the tension of the wire rope to DIN 1480.\n\nMinor differences between the printed image and the original product may exist.\n\n ", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "use", "DIN", "wire rope", "ZQ series", "printed image", "exact adjustment", "original product", "Minor differences", "Pull Wire Switches", "Schmersal Tensioner", "Schmersal tensioning", "M6-TENSIONING JACK-SS316", "wire emergency stop switches" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 179, "imageuri": "https://productimages.withfloats.com/actual/63f6f50cd3b78d0001877e2e.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63f6f50cd3b78d0001877e2e.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-23T05:09:28.323Z", "updatedon": "2025-07-16T10:20:26.409Z", "buyonlinelink": null, "producturl": "http://WWW.LADDERLOGIXINDIA.COM/products/m6-for-pull-wire-switches/179", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL ", "category": "M6 for Pull Wire Switches", "tags": [ "M6-TENSIONING JACK-SS316 In Vadodara ", "M6-TENSIONING JACK-SS316 In India " ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "63ef1472878f9600010898a6", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Schmersal Connector Cables ", "description": "A-K5P-M12-S-G-5M-BK-2-X-A-1 - Schmersal Connector Cables - M12 Connector, 5 Pole with 5 Meter Pre-wired Cable", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "5 Pole", "G-5M-BK", "M12 Connector", "5 Meter Pre-wired Cable", "Schmersal Connector Cables" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 174, "imageuri": "https://productimages.withfloats.com/actual/63ef147820f30600019de9ad.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63ef147820f30600019de9ad.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-17T05:45:22.498Z", "updatedon": "2025-07-16T10:23:14.018Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM//schmersal-connector-cables-/174", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL ", "category": "Schmersal Connector Cables ", "tags": [ "A-K5P-M12-S-G-5M-BK-1-X-A-1 In Vadodara ", "A-K5P-M12-S-G-5M-BK-1-X-A-1 In India " ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "63ef1153283db8000193bd01", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Connector Cables ", "description": "A-K4P-M12-S-G-5M-BK-1-X-A-1 - Schmersal Connector Cables - M12 Connector, 4 Pole with 5 Meter Pre-wired Cable", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "BK", "G-5M", "4 Pole", "5 Meter", "wired Cable", "M12 Connector", "Schmersal Connector Cables" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 173, "imageuri": "https://productimages.withfloats.com/actual/63ef115820f30600019de601.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63ef115820f30600019de601.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-17T05:32:03.125Z", "updatedon": "2025-07-16T10:24:07.139Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM/products/connector-cables-/173", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL ", "category": "Connector Cables - M12 ", "tags": [ "Connector Cables in India", "Connector Cables supplier in Vadodara" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "63eb1d6104974c0001de5e5a", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": " CABLE PULL SWITCH", "description": "ZQ 900-22\n3 cable entries M 20 x 1.5\nMetal enclosure\none-side operation / wire up to 75 m long\nRelease push button\nPosition indicator\nRobust design\nLarge wiring compartment\nTwisting of towing eye not possible\nExternal watertight collar\nwire pull and breakage detection", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "ZQ", "eye", "Twisting", "wire pull", "Robust design", "3 cable entries", "Metal enclosure", "one-side operation", "Position indicator", "breakage detection", "Release push button", "Large wiring compartment", "External watertight collar" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 159, "imageuri": "https://productimages.withfloats.com/actual/63eb1d643bbe8a0001a400cc.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/63eb1d643bbe8a0001a400cc.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2023-02-14T05:34:25.33Z", "updatedon": "2025-07-17T04:36:57.08Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM//-cable-pull-switch/159", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "SCHMERSAL", "category": " CABLE PULL SWITCH", "tags": [ "CABLE PULL SWITCH in India", "CABLE PULL SWITCH supplier in Vadodara" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e191da2024c00014bc31f", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KCD2-UT2-Ex1", "description": "1-channel isolated barrier\n24 V DC supply (Power Rail)\nThermocouple, RTD, potentiometer or voltage input\nCurrent output 0/4 mA ... 20 mA\nSink or source mode\nConfigurable by PACTware\nLine fault (LFD) and sensor burnout detection\nUp to SIL 2 acc. to IEC 61508/IEC 61511\nGeneral specifications\nSignal type\tAnalog input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSupply\nConnection\tterminals 9+, 10- or power feed module/Power Rail\nRated voltage\t19 ... 30 V DC\nRipple\twithin the supply tolerance\nPower dissipation\t≤ 0.98 W\nPower consumption\tmax. 0.98 W\nInterface\nProgramming interface\tprogramming socket\nInput\nConnection side\tfield side\nConnection\tterminals 1, 2, 3, 4\nRTD\ttype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)\ntype Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)\ntype Cu10, Cu50, Cu100 (P50353-92)\ntype Ni100 (DIN 43760)\nMeasuring current\tapprox. 200 µA with RTD\nTypes of measuring\t2-, 3-, 4-wire connection\nLead resistance\tmax. 50 Ω per line\nMeasurement loop monitoring\tsensor breakage, sensor short-circuit\nThermocouples\ttype B, E, J, K, N, R, S, T (IEC 584-1: 1995)\ntype L (DIN 43710: 1985)\ntype TXK, TXKH, TXA (P8.585-2001)\nCold junction compensation\texternal and internal\nMeasurement loop monitoring\tsensor breakage\nPotentiometer\t0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)\nVoltage\tselectable within the range -100 ... 100 mV\nInput resistance\t≥ 1 MΩ (-100 ... 100 mV)\nOutput\nConnection side\tcontrol side\nConnection\tterminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+)\nOutput\tAnalog current output\nCurrent range\t0 ... 20 mA or 4 ... 20 mA\nFault signal\tdownscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)\nSource\tload 0 ... 550 Ω\nopen-circuit voltage ≤ 18 V\nSink\tVoltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,\nseries resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.\nThe maximum value of the resistance is (V - 5)/0.0215 Ω.\nTransfer characteristics\nDeviation\t\nAfter calibration\tPt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection))\nthermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S)) , includes ± 1.3 K fault of the cold junction compensation (CJC)\nmV: ± (50 µV + 0.1 % of span)\npotentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance))\nInfluence of ambient temperature\tPt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)\nthermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) included\nmV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)\npotentiometer: ± 0.006 % of span/K ΔTamb*)\n*) ΔTamb = ambient temperature change referenced to 23 °C (296 K)\nInfluence of supply voltage\t< 0.01 % of span\nInfluence of load\t≤ 0.001 % of output value per 100 Ω\nReaction time\tworst case value (sensor breakage and/or sensor short circuit detection enabled)\nmV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s\nGalvanic isolation\nOutput/supply, programming input\tfunctional insulation, rated insulation voltage 50 V AC\nThere is no electrical isolation between the programming input and the supply.\nThe programming cable provides galvanic isolation so that ground loops are avoided.\nIndicators/settings\nDisplay elements\tLEDs\nConfiguration\tvia PACTware\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nConformity\nElectromagnetic compatibility\tNE 21:2012\nEN 61326-3-2:2008\nDegree of protection\tIEC 60529:2001\nProtection against electrical shock\tUL 61010-1:2004\nAmbient conditions\nAmbient temperature\t-20 ... 70 °C (-4 ... 158 °F)\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 100 g\nDimensions\t12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tBASEEFA 13 ATEX 0102 X\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I\nInput\t[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\nInputs\tterminals 1, 2, 3, 4\nVoltage Uo\t9 V\nCurrent Io\t13.1 mA\nPower Po\t30 mW\nAnalog outputs, power supply, collective error\t\nMaximum safe voltage\t250 V (Attention! This is not the rated voltage.)\nInterface\t\nMaximum safe voltage\t250 V (Attention! The rated voltage is lower.), RS 232\nCertificate\tBASEEFA 13 ATEX 0103 X\nMarking\tEx-Hexagon II 3G Ex nA II T4 Gc [device in zone 2]\nGalvanic isolation\t\nInput/Other circuits\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010\nInternational approvals\nUL approval\t\nControl drawing\t116-0379 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx BAS 13.0057X\nIECEx marking\t[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "1 s", "Ex ia Da", "Ex ia Ma", "Ex ia Ga", "V DC supply", "output value", "x 119 x 114 mm", "measurement value", "reference temperature", "voltage peak value 375", "insulation voltage 50 V", "electrical isolation acc", "cold junction compensation", "ambient temperature change", "sensor short circuit detection" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 59, "imageuri": "https://productimages.withfloats.com/actual/635e191fe52a05000198be38.png", "tileimageuri": "https://productimages.withfloats.com/tile/635e191fe52a05000198be38.png", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T06:26:37.668Z", "updatedon": "2022-10-30T06:26:37.668Z", "buyonlinelink": null, "producturl": "http://WWW.LADDERLOGIXINDIA.COM/products/kcd2-ut2-ex1/59", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": "Universal Temperature Converter", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e110bf7c0e00001ca7e77", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KCD2-STC-Ex1.2O", "description": "1-channel isolated barrier\n24 V DC supply (Power Rail)\nInput for 2-wire SMART transmitters and current sources\nSignal splitter (1 input and 2 outputs)\nDual output 0/4 mA ... 20 mA or 0/1 V ... 5 V\nTerminal blocks with test sockets\nSIL 2 (SC 3) acc. to IEC/EN 61508\nGeneral specifications\nSignal type\tAnalog input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSystematic capability (SC)\tSC 3\nSupply\nConnection\tPower Rail or terminals 9+, 10-\nRated voltage\t19 ... 30 V DC\nRipple\twithin the supply tolerance\nPower dissipation\tapprox. 1.4 W at 20 mA transfer current, 250 Ω in both outputs\nPower consumption\t2 W\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2- (sink); 3+, 4- (source)\nInput signal\t0/4 ... 20 mA\nVoltage drop\tterminals 3, 4: ≤ 6.1 V at 20 mA\nShort-circuit current\tterminals 1+, 2-: 25 mA\nInput resistance\tterminals 1+, 2-: max. 500 Ω (BRAIN)\n(250 Ω load)\nAvailable voltage\tterminals 1+, 2-: ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA\nOutput\nConnection side\tcontrol side\nConnection\tsource: terminals 5-, 6+; 7-, 8+\nsink: terminals 5+, 6-, 7+, 8-\nLoad\tchannel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V)\nchannel 2: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V)\nOutput signal\t0/4 ... 20 mA or 0/1 ... 5 V\nRipple\tmax. 50 µA rms\nTransfer characteristics\nDeviation\tIout < 20 µA (0.1 %); Vout < 10 mV (0.2 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 °C (68 °F), 0/4 ... 20 mA, 0/1 ... 5 V\nInfluence of ambient temperature\tcurrent output: 0.25 µA/K\nvoltage output: 80 µV/K\nFrequency range\tfield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 6 kHz (-3 dB)\ncontrol side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 6 kHz (-3 dB)\nSettling time\t6 ms\nRise time/fall time\t2 ms\nGalvanic isolation\nOutput/power supply\tfunctional insulation, rated insulation voltage 50 V AC\nOutput/Output\tfunctional insulation, rated insulation voltage 50 V AC\nIndicators/settings\nDisplay elements\tLED\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nConformity\nElectromagnetic compatibility\tNE 21:2012\nEN 61326-3-2:2008\nDegree of protection\tIEC 60529:2001\nProtection against electrical shock\tUL 61010-1:2012\nAmbient conditions\nAmbient temperature\t-20 ... 60 °C (-4 ... 140 °F)\nextended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 100 g\nDimensions\t12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tBASEEFA 13 ATEX 0077 X\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC\nEx-Hexagon II (1)D [Ex ia Da] IIIC\nEx-Hexagon I (M1) [Ex ia Ma] I\nInput\t[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\nSupply\t\nMaximum safe voltage\t250 V (Attention! The rated voltage can be lower.)\nEquipment\tterminals 1+, 2-\nVoltage\t25.2 V\nVoltage\t28.2 V\nCurrent\t93 mA\nPower\t656 mW\nInternal capacitance\t10 nF\nInternal inductance\t0 mH\nEquipment\tterminals 3+, 4-\nVoltage\t30 V\nCurrent\t115 mA\nPower\t700 mW\nVoltage\t5 V\nCurrent\t6.8 mA\nPower\t1.6 mW\nOutput\t\nMaximum safe voltage\t250 V (Attention! The rated voltage can be lower.)\nCertificate\tBASEEFA 13 ATEX 0078 X\nMarking\tEx-Hexagon II 3G Ex nA II T4 Gc [device in zone 2]\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010\nInternational approvals\nUL approval\t\nControl drawing\t116-0380 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx BAS 13.0043X\nIECEx marking\t[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\n", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "5 V", "1 input", "Ex ia Da", "Ex ia Ma", "Ex ia Ga", "V DC supply", "Vpp signal 0", "supply voltage", "20 mA transfer current", "voltage peak value 375", "insulation voltage 50 V", "electrical isolation acc", "ambient temperature range", "35 mm DIN mounting rail acc" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 51, "imageuri": "https://productimages.withfloats.com/actual/635e110be52a05000198bd1d.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/635e110be52a05000198bd1d.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T05:52:11.653Z", "updatedon": "2022-10-30T05:52:11.653Z", "buyonlinelink": null, "producturl": "http://WWW.LADDERLOGIXINDIA.COM/products/kcd2-stc-ex1-2o/51", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": " SMART Transmitter Power Supply", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e0f90f7c0e00001ca7e6f", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KFD2-STC5-Ex1.2O", "description": "\n1-channel isolated barrier\n24 V DC supply (Power Rail)\nInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\nSignal splitter (1 input and 2 outputs)\nDual output 4 mA ... 20 mA current sink/current source\nTerminals with test points\nSIL 2 (SC 3) acc. to IEC/EN 61508\nGeneral specifications\nSignal type\tAnalog input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSystematic capability (SC)\tSC 3\nSupply\nConnection\tPower Rail or terminals 14+, 15-\nRated voltage\t18 ... 30 V DC\nRipple\twithin the supply tolerance\nPower dissipation\t≤ 1 W at maximum load\nPower consumption\t≤ 1.7 W at maximum load\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2-, 3\nInput signal\t4 ... 20 mA\nOpen circuit voltage/short-circuit current\tterminals 1+, 3: 23 V / 25 mA\nInput resistance\tmax. 265 Ω terminals 2-, 3 , max. 330 Ω terminals 1+, 3\nAvailable voltage\t≥ 16 V at 20 mA ; ≥ 20 V at 4 mA , terminals 1+, 3\nOutput\nConnection side\tcontrol side\nConnection\tterminals 7+, 8-, 9-; 10+, 11-, 12- (sink)\nterminals 7-, 8+, 9+; 10-, 11+, 12+ (source)\nsee additional information\nLoad\t0 ... 600 Ω\nOutput signal\t4 ... 20 mA (overload > 25 mA)\nRipple\tmax. 50 µA rms\nExternal supply (loop)\t2 ... 30 V DC\nIf the external voltage is > 19 V, a load ≥ ((V - 19) / 0.02) Ω is required. V represents the value of the external voltage.\nThe internal 250 Ω resistor at terminals 9 and 12 can be used as a load.\nTransfer characteristics\nDeviation\tat 20 °C (68 °F), 4 ... 20 mA\n≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage\nInfluence of ambient temperature\t≤ 0.25 µA/K\nFrequency range\tfield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB)\ncontrol side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB)\nSettling time\t200 µs\nRise time/fall time\t100 µs\nGalvanic isolation\nOutput/power supply\tfunctional insulation, rated insulation voltage 50 V AC\nOutput/Output\tfunctional insulation, rated insulation voltage 50 V AC\nIndicators/settings\nDisplay elements\tLED\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nConformity\nElectromagnetic compatibility\tNE 21:2012\nEN 61326-3-2:2008\nDegree of protection\tIEC 60529:2001\nProtection against electrical shock\tUL 61010-1:2012\nAmbient conditions\nAmbient temperature\t-20 ... 60 °C (-4 ... 140 °F)\nextended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 200 g\nDimensions\t20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) (W x H x D) , housing type B2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tCML 17 ATEX 2031X\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC\nEx-Hexagon II (1)D [Ex ia Da] IIIC\nEx-Hexagon I (M1) [Ex ia Ma] I\nInput\t[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\nSupply\t\nMaximum safe voltage\t250 V (Attention! The rated voltage can be lower.)\nEquipment\tterminals 1+, 3-\nVoltage\t26.2 V\nVoltage\t27.25 V\nCurrent\t93 mA\nPower\t634 mW\nEquipment\tterminals 2-, 3\nVoltage\t30 V\nCurrent\t115 mA\nPower\tmax 1 W\nVoltage\t2 V\nCurrent\t8.5 mA\nPower\t4.3 mW\nEquipment\tterminals 1+, 2 / 3-\nVoltage\t26.2 V\nVoltage\t27.25 V\nCurrent\t115 mA\nPower\t784 mW\nCertificate\tCML 17 ATEX 3030X\nMarking\tEx-Hexagon II 3G Ex ec IIC T4 Gc\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11:2007, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012\nInternational approvals\nUL approval\tE106378\nControl drawing\t116-0439 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx CML 17.0016X\nIECEx marking\t[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I\nEx ec IIC T4 Gc", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "20 V", "30 V", "Ex ia Da", "Ex ia Ma", "Ex ia Ga", "V DC supply", "output 4 mA", "20 mA current", "external voltage", "II 3G Ex ec IIC T4", "voltage peak value 375", "insulation voltage 50 V", "electrical isolation acc", "ambient temperature range", "35 mm DIN mounting rail acc" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 50, "imageuri": "https://productimages.withfloats.com/actual/635e0f910c93040001f7c338.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/635e0f910c93040001f7c338.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T05:45:52.066Z", "updatedon": "2022-10-30T05:45:52.066Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM/products/kfd2-stc5-ex1-2o/50", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": " SMART Transmitter Power Supply", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "635e0b9544ad890001abb9fc", "fptag": "LADDERLOGIX", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "KCD2-STC-Ex1", "description": "1-channel isolated barrier\n24 V DC supply (Power Rail)\nInput for 2-wire SMART transmitters and current sources\nOutput for 4 mA ... 20 mA or 1 V ... 5 V\nHousing width 12.5 mm\nSIL 2 (SC 3) acc. to IEC/EN 61508\n\nGeneral specifications\nSignal type\tAnalog input\nFunctional safety related parameters\nSafety Integrity Level (SIL)\tSIL 2\nSystematic capability (SC)\tSC 3\nSupply\nConnection\tPower Rail or terminals 9+, 10-\nRated voltage\t19 ... 30 V DC\nRipple\t≤ 10 %\nRated current\t≤ 45 mA at 24 V and 20 mA source mode output\nPower dissipation\t≤ 800 mW\nPower consumption\t≤ 1.1 W\nInput\nConnection side\tfield side\nConnection\tterminals 1+, 2-; 3+, 4-\nInput signal\t4 ... 20 mA limited to approx. 26 mA\nOpen circuit voltage/short-circuit current\tterminals 1+, 2-: 22 V / 26 mA\nVoltage drop\tterminals 3+, 4- : approx. 5 V\nAvailable voltage\tterminals 1+, 2-: ≥ 15 V at 20 mA ; ≥ 18 V at 4 mA\nOutput\nConnection side\tcontrol side\nConnection\tterminals 5-, 6+\nterminals 5-, 8+ for HART resistor\nLoad\t0 ... 350 Ω (source mode)\nOutput signal\t4 ... 20 mA or 1 ... 5 V (on 250 Ω, 0.1 % internal shunt)\n4 ... 20 mA (sink mode), operating voltage 10 ... 30 V\nRipple\t20 mV rms\nTransfer characteristics\nDeviation\tat 20 °C (68 °F)\n< 0.1 % of full scale, incl. non-linearity and hysteresis (source mode and sink mode 4 ... 20 mA)\n≤ ± 0.2 % incl. non-linearity and hysteresis (source mode 1 ... 5 V)\nInfluence of ambient temperature\t< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode and sink mode 4 ... 20mA)\n< 0.5 mV/K (-20 ... 70 °C (-4 ... 158 °F)); < 1 mV/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode 1...5 V)\nFrequency range\tfield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)\ncontrol side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)\nSettling time\t≤ 50 ms\nRise time/fall time\t≤ 10 ms\nGalvanic isolation\nInput/Output\tbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nInput/power supply\treinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nOutput/power supply\tbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff\nIndicators/settings\nDisplay elements\tLED\nControl elements\tDIP switch\nConfiguration\tvia DIP switches\nLabeling\tspace for labeling at the front\nDirective conformity\nElectromagnetic compatibility\t\nDirective 2014/30/EU\tEN 61326-1:2013 (industrial locations)\nConformity\nElectromagnetic compatibility\tNE 21:2017\nEN 61326-3-2:2018\nDegree of protection\tIEC 60529:2001\nProtection against electrical shock\tUL 61010-1:2012\nAmbient conditions\nAmbient temperature\t-40 ... 70 °C (-40 ... 158 °F)\nMechanical specifications\nDegree of protection\tIP20\nConnection\tscrew terminals\nMass\tapprox. 100 g\nDimensions\t12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2\nMounting\ton 35 mm DIN mounting rail acc. to EN 60715:2001\nData for application in connection with hazardous areas\nEU-type examination certificate\tCESI 06 ATEX 021\nMarking\tEx-Hexagon II (1)G [Ex ia Ga] IIC\nEx-Hexagon II (1)D [Ex ia Da] IIIC\nEx-Hexagon I (M1) [Ex ia Ma] I\nInput\tEx ia\nSupply\t\nMaximum safe voltage\t250 V AC (Attention! Um is no rated voltage.)\nEquipment\tterminals 1+, 2-\nVoltage\t25.2 V\nCurrent\t100 mA\nPower\t630 mW\nInternal capacitance\t5.7 nF\nInternal inductance\tnegligible\nEquipment\tterminals 3+, 4-\nVoltage\t30 V\nCurrent\t128 mA\nVoltage\t7.2 V\nCurrent\t100 mA\nPower\t25 mW\nInternal capacitance\t5.7 nF\nInternal inductance\tnegligible\nCertificate\tCESI 19 ATEX 021 X\nMarking\tEx-Hexagon II 3G Ex ec IIC T4 Gc\nGalvanic isolation\t\nInput/Output\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nInput/power supply\tsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V\nDirective conformity\t\nDirective 2014/34/EU\tEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-7:2015\nInternational approvals\nFM approval\t\nFM certificate\tFM 18 CA 0116 X , FM 19 US 0117 X\nControl drawing\t116-0469 (cFMus)\nUL approval\tE106378\nControl drawing\t116-0459 (cULus)\nIECEx approval\t\nIECEx certificate\tIECEx CES 06.0001X\nIECEx marking\t[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I\nEx ec IIC T4 Gc", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "1 V", "5 V", "4 mA", "mode 4", "V DC supply", "Vpp signal 0", "source mode 1", "20 mA source mode", "II 3G Ex ec IIC T4", "operating voltage 10", "insulation voltage 300", "voltage peak value 375", "electrical isolation acc", "SMART Transmitter Power Supply" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 49, "imageuri": "https://productimages.withfloats.com/actual/635e0b97bb77e100018dfb6c.jpg", "tileimageuri": "https://productimages.withfloats.com/tile/635e0b97bb77e100018dfb6c.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2022-10-30T05:28:53.901Z", "updatedon": "2022-10-30T05:36:42.667Z", "buyonlinelink": null, "producturl": "https://LADDERLOGIX.NOWFLOATS.COM/products/kcd2-stc-ex1/49", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "PEPPERL-FUCHS", "category": "SMART Transmitter Power Supply", "tags": [], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
wire?

Still searching for
wire?

Chat with us